Home / Products

COLD ROOM PRODUCTS

Cold Room Equipment for Chilled and Frozen Storage

JILAN supplies the main components used to build commercial cold rooms: insulated panels, cold room doors, refrigeration equipment, controls and installation accessories. Source a coordinated equipment set for a new project, or request selected components for local assembly, replacement or system upgrades.
PRODUCT RANGE

Cold room products we supply.

Compare the main product categories below, then open a category page for construction options, specifications and selection information.
P
01

Cold Room Panels

Insulated panels create the walls, ceiling and, where required, the floor of the cold room. Panel construction is selected according to the target temperature, room use, installation conditions and project requirements.

PU / PIR options
Wall · ceiling · floor
Cam-lock connection
Project-specific dimensions

View Cold Room Panels →

D
02

Cold Room Doors

Cold room doors provide insulated access while helping control air infiltration during operation. The appropriate door type depends on the clear opening, traffic pattern, target temperature and handling method.
Hinged doors
Sliding doors
Project-specific openings
Safety release options
Enquire About Cold Room Doors →
R
03

Cold Room Refrigeration Equipment

Cold room refrigeration equipment removes heat from the room and maintains the target temperature. The equipment combination is selected using the project conditions and calculated cooling load, rather than room volume alone.
Condensing units
Unit coolers
Cold room evaporators
Refrigeration controls

Enquire About Refrigeration Equipment →

A
04

Controls and Accessories

Controls and accessories support temperature management, equipment operation, access and installation. The required items are confirmed according to the selected panels, doors and refrigeration equipment.

Temperature controls

Electrical boxes
Lighting
Installation accessories

Ask About Accessories →

PRODUCT OVERVIEW

Which cold room equipment do you need?

Use the comparison below as a starting point. Final selection depends on the complete project conditions.
CATEGORY
MAIN FUNCTION
KEY SELECTION INFORMATION
NEXT STEP
Cold room panels
Form the insulated room envelope
Target temperature, dimensions, panel application and finish
View Cold Room Panels
Cold room doors
Provide insulated access
Opening size, traffic, target temperature and door type
View Cold Room Doors
Refrigeration equipment
Remove heat and maintain target temperature
Cooling load, ambient conditions, daily loading and power supply
View Refrigeration Equipment
Controls and accessories
Support control, operation and installation
Equipment configuration and operating requirements
Enquire with project details
EQUIPMENT SELECTION

What information should you send?

These details help identify the suitable panel construction, door configuration and refrigeration equipment scope. Final technical selection must be confirmed against the complete project conditions.
01

Internal dimensions

L × W × H
02

Stored product

Product type and quantity
03

Target temperature

Required room condition
04

Product entry temperature

Temperature before storage
05

Daily loading

Quantity introduced each day
06

Ambient conditions

Country and local temperature
07

Door use

Opening size and frequency
08

Power supply

Voltage · frequency · phase
SUPPLY SCOPE

Complete equipment set or individual components.

1

New Cold Room

Request panels, doors, refrigeration equipment, controls and required accessories under one itemized product proposal.
2

Individual Products

Request selected panels, doors, condensing units, unit coolers or controls using an existing specification or equipment schedule.
3

Replacement or Upgrade

Send the existing nameplate, model, refrigerant, power supply, target temperature and clear photographs for compatibility review.
Need room-type planning, temperature guidance or application recommendations rather than individual equipment?
Explore Cold Room Solutions →
FREQUENTLY ASKED

Cold room equipment FAQs.

A typical cold room uses insulated wall and ceiling panels, an insulated floor where required, a cold room door, a condensing unit, a unit cooler or evaporator, electrical controls, temperature controls, lighting and installation accessories. The exact equipment list depends on the room design and operating conditions.

Yes. Panels, doors and refrigeration equipment can be requested individually for contractor supply, replacement or system upgrades. Send the required specifications so the proposed product can be checked against your application.

Cold room refrigeration equipment commonly includes a condensing unit, unit cooler or evaporator, controls and related refrigeration components. The required combination depends on the target temperature, cooling load, ambient conditions, refrigerant type and local power supply.

Refrigeration equipment is selected from the calculated cooling load and operating conditions, not room volume alone. Important inputs include insulation, target temperature, ambient temperature, stored product, product entry temperature, daily loading and door use.

Send the existing equipment model and nameplate, refrigerant, voltage, frequency and phase, target temperature, room dimensions, stored product, fault or replacement reason and clear equipment photographs.

Yes. Equipment can be reviewed and configured according to the destination voltage, frequency and phase. Provide these details with your enquiry so the appropriate electrical configuration can be confirmed.

Tell us which equipment you need

Send a product list or share your project conditions for an itemized equipment proposal.
Your information is used only to review and respond to your enquiry.